Make sure to follow all these steps before using the Ace laser cutter
- Close Hallway Door then Turn On Honeywell Filter
- Log into Laser Access Box by tapping your fob
- Check the filter in the filter box
- Ensure that the filter type in the box matches the one on the Access Box screen
- Check that the filter you’re about to use looks OK, if it looks like it might be too used, replace it
- Turn on system with Main Switch
- Confirm air compressor is running with your foot
- Confirm chiller is on and that the temperature is in the right range (19°-22°)
- Do a draw test with the folded test paper
- From the laser control panel, use the MENU button to reset the bed (Z-Axis reset)